The National Transportation Safety Board Outlines Pittsburgh Bridge Collapse

The National Transportation Safety Board Outlines Pittsburgh Bridge Collapse

PennDOT announces selection of the team to rebuild fallen Fern Hollow Bridge.

Officials in Pennsylvania are moving forward on building a replacement for the Fern Hollow Bridge in Pittsburgh, which collapsed on January 28, selecting a team of HDR Inc. and Swank Construction to design and construct the new structure and the approval of $25.3 million in federal funds for the project. The team "mobilized to the site an February 3 and began work," Pennsylvania Dept. of Transportation spokesperson Alexis Campbell said.

According to an article, the National Transportation Safety Board, which has launched an in-depth probe of the collapse, has released an interim report of the accident, which caused no fatalities but resulted in injuries to 10 people in vehicles that were on the bridge at the time of the collapse. As expected, the report, issued on February 7, includes factual details, but does not contain findings of the collapse's probable cause. That finding will be part of the NTSB’s final report, which will not be finished for perhaps 12 to 18 months, according to Chair Jennifer Homendy.

The interim report does, however, include some specific details. For example, it states, “Initial assessment of bridge components indicates that the collapse initiated at the west end of the structure.”

“Although certain areas of the welded steel girders were identified as being fracture critical, no primary fractures were found in these areas.” The report also states that “further examination will be performed as debris from the bridge is removed and unobstructed access becomes available.”

In addition, the NTSB report describes the 447-foot-long, four-lane bridge in detail, noting that it “was an uncoated weathering steel, three-span, continuous rigid 'K' frame structure with two welded steel girders, welded steel floor beams and rolled steel stringers.” The report continues. "The ends of the structure rested on reinforced concrete caps on stone masonry abutments. Each girder was additionally supported by two inclined, welded steel frame legs, also made of uncoated weathering steel, which rested atop concrete thrust blocks.”

NTSB also indicated that its investigation will cover the bridge’s design, condition, maintenance, rehabilitation, inspection and load-rating history. It added that it plans a forensic examination of several of the bridge's structural components, and said, “The recovery of evidence, including extraction and documentation, is expected to be a lengthy process.”

NTSB said, “All aspects of the collapse remain under investigation while the NTSB determines the probable cause, with the intent of issuing safety recommendations to prevent similar events.”

The report recounts details of the collapse, many reported earlier by media outlets. At about 6:40 a.m., when the bridge fell about 100 feet into Frick Park below, four passenger vehicles and an articulated Port Authority of Allegheny County bus were on the bridge. A fifth vehicle drove off the east abutment, according to NTSB. The bridge had a posted weight limit of 26 tons.

The Federal Highway Administration said that on February 1, it authorized PennDOT to use $25.3 million in federal formula funding for the project. Of that, $22.6 million will come from the Highway Infrastructure Program’s bridge replacement and rehabilitation funds. The other $2.7 million from the National Highway Performance Program.

Product Showcase

  • Kestrel 5400 Heat Stress Tracker WBGT Monitoring for Workplace Safety

    Ensure safety with the Kestrel® 5400 Heat Stress Tracker, the go-to choice for safety professionals and endorsed by the Heat Safety & Performance Coalition. This robust, waterless WBGT meter is ideal for both indoor and outdoor environments, offering advanced monitoring and data logging essential for OSHA compliance. It features pre-programmed ACGIH guidelines and alert settings to quickly signal critical conditions. Integrated with the cloud-based Ambient Weather Network, the 5400 allows managers to view, track, and log job site conditions remotely, ensuring constant awareness of potential hazards. Its capability for real-time mobile alerts and remote data access promotes proactive safety management and workplace protection, solidifying its role as a crucial tool in industrial hygiene. Read More

  • SwabTek® Cannabis Test Kit

    The SwabTek® Cannabis Test Kit is a single-use spot test designed for use in screening for cannabis compounds in any sample type or on any surface. The test is capable of identifying the presumed presence of cannabinoids in very small quantities, with a level of detection as little as 6 μg in mass. Learn more about the SwabTek® Cannabis Test Kit and the rest of SwabTek surface drug testing solutions through the webinar titled "Everything You Want To Know About Surface Testing" Read More

  • Glove Guard® Clip

    Safety should never be compromised, especially when it comes to proper glove usage. The Glove Guard® clip enhances safety by encouraging employees to keep their gloves with them at all times. This reduces the risk of accidents and injuries on the job. By ensuring everyone has their gloves readily available, we help promote a culture of safety and efficiency. The Glove Guard® clip is designed to withstand the toughest work environments. Constructed from robust materials made in the USA, it can endure extreme conditions, including harsh weather, and rigorous activities. Read More

Featured

Artificial Intelligence

Webinars