FRA Requires Retrofitting of Unapproved Tank Car Valves

The agency's March 13 order gives owners 60 days to replace any 3-inch McKenzie UNNR ball valve in a tank car used to transport any hazardous material described in 49 CFR 172.101 and 90 days to remove the 1-inch and 2-inch valves.

A recent Railworthiness Directive from the s Federal Railroad Administration orders railroad tank car owners to replace unapproved valves that are installed in some tank cars. They are UNNR ball valves manufactured and sold by McKenzie Valve & Machining LLC. FRA's announcement said its investigations showed the valves are not approved for use on railroad tank cars and that the 3-inch ball valve, when not properly configured, is causing tank cars to leak.

"The problem was first discovered when multiple FRA investigations identified several railroad tank cars leaking small quantities of hazardous materials. One instance occurred during the week of January 11th and involved a train of 100 tank cars loaded with crude oil being transported by BNSF Railway Company from Tioga, North Dakota, to a refinery in Anacortes, Washington," it stated. "BNSF discovered 14 tank cars leaking crude oil on the route. The FRA then inspected seven of the identified leaking tank cars that BNSF removed from the train in Vancouver, WA. The FRA inspector observed each of the tank car's top fittings and found product leaking from the liquid line ball valves and around each valve's closure plug. Further tests conducted by the FRA found that certain closure plugs installed on the 3" valves caused mechanical damage and led to the destruction of the valves' seal integrity. In addition, testing found that when a 3" closure plug was applied and tightened in the 3" McKenzie valve, the plug contacted and damaged the ball. Further testing revealed that the application of downward force on the valve ball applied by the 3" plug resulted in the over-compression, damage, and misalignment of the inboard seal, causing the valve to leak."

Additional tests concluded the McKenzie 1-inch and 2-inch ball valves do not appear to present the same safety concerns as the 3-inch valves, but they are not approved for use on railroad tank cars and so must be replaced. FRA as of March 13 was not aware of any non-accident releases or other releases from railroad tank cars involving the smaller valves. The agency also said if McKenzie can adequately demonstrate the safety of the 1-inch and 2-inch valves and obtains approval for the use of those valves on tank cars, cars equipped with them may be returned to hazmat service.

The agency's March 13 order gives owners 60 days to replace any 3-inch McKenzie UNNR ball valve in a tank car used to transport any hazardous material described in 49 CFR 172.101 and 90 days to remove the 1-inch and 2-inch valves.

The DOT agency said federal regulations require all valves applied to tank cars must be of an approved design by the Association of American Railroads Tank Car Committee, and FRA's investigations "demonstrate clear inconsistencies between the type of valve design that AAR approved versus the design of the valve actually being used, which raises questions about the approval process and a manufacturer’s adherence to an approved design type." FRA announced it will immediately begin working with AAR to commence a full audit of the association's process for approving tank car valves and other components in order to prevent incidents like this from occurring again.

"Ensuring the safe transport of hazardous materials is a top priority for the Department of Transportation," said U.S. Transportation Secretary Anthony Foxx. "I expect this audit to force a stricter adherence to the structures in place to keep our railways safe."

Product Showcase

  • SECUPRO MARTEGO

    FOR HIGHEST DEMANDS. A cutting tool in which function and design go hand in hand. Meet the SECUPRO MARTEGO, our prize-winning squeeze-grip safety knife with fully automatic retractable blade for safety. • Ergonomically friendly trigger mechanism to engage the blade • Durable body made of aluminum • Safer alternative to fixed blade utility knives for general cutting tasks • 9 mm Cutting depth • Easy, tool free blade change Dimensions: L 6.10" L x 0.71" W x 1.91" H Weight: 3.70 oz Cutting Depth: 9 mm Read More

  • Kestrel 5400 Heat Stress Tracker WBGT Monitoring for Workplace Safety

    Ensure safety with the Kestrel® 5400 Heat Stress Tracker, the go-to choice for safety professionals and endorsed by the Heat Safety & Performance Coalition. This robust, waterless WBGT meter is ideal for both indoor and outdoor environments, offering advanced monitoring and data logging essential for OSHA compliance. It features pre-programmed ACGIH guidelines and alert settings to quickly signal critical conditions. Integrated with the cloud-based Ambient Weather Network, the 5400 allows managers to view, track, and log job site conditions remotely, ensuring constant awareness of potential hazards. Its capability for real-time mobile alerts and remote data access promotes proactive safety management and workplace protection, solidifying its role as a crucial tool in industrial hygiene. Read More

  • NoiseCHEK Personal Noise Dosimeter

    SKC NoiseCHEK is the easiest-to-use dosimeter available! Designed specifically for OEHS professionals, SKC NoiseCHEK offers the easiest operation and accurate noise measurements. Everything you need is right in your palm. Pair Bluetooth models to your mobile devices and monitor workers remotely with the SmartWave dB app without interrupting workflow. Careful design features like a locking windscreen, sturdy clip, large front-lit display, bright status LEDs, and more make NoiseCHEK the top choice in noise dosimeters. Demo NoiseCHEK at AIHA Connect Booth 1003. Read More

Featured

Artificial Intelligence