NIOSH Undertakes Service-Life Indicator Rulemaking

Earlier SCBA alarms would be important protection for firefighters. Meanwhile, NFPA is moving to change its NFPA 1981 standard to require that indicators alarm at 33 percent of rated service time.

Firefighters have a stake in a new NIOSH rulemaking that would set 25 percent as the default setting for remaining service-life indicators on open-circuit self-contained breathing apparatus. The manufacturer would have the option of setting it higher at the purchaser's discretion, however.

Comments are due by Aug. 24 and should be submitted via www.regulations.gov with the title "Open-Circuit Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance Requirements, RIN 0920-AA38" and should identify the author(s), return address, and a phone number, in case clarification is needed. The agency asked for comments specifically on these questions:

  • Is 25 percent of the rated service time of the respirator an appropriate default setting for the indicator?
  • Should the rule specify an upper limit that would require that the indicator be set to alarm no earlier than a set amount, such as 50 percent of rated service time?
  • Are there possible emergency or rescue scenarios for which one would want an indicator to alarm at 50 percent or more of the rated service time?

Open-circuit self-contained breathing apparatus mainly are used by firefighters and other rescue workers in environments that may be immediately dangerous to life and health (IDLH). Currently, the requirement is for the indicator to alarm when the rated service time of the respirator is down to within 20 to 25 percent. After receiving a petition to initiate this rulemaking, NIOSH asked stakeholders for their input and began working on this change; NFPA recently proposed amending NFPA 1981, Standard on Open-Circuit Self-Contained Breathing Apparatus (SCBA) for Emergency Services, in its 2013 edition to require that the indicator alarm at 33 percent, according to the NIOSH proposal.

The issue is highly important because NFPA studies have shown most firefighter deaths in large structure fires are caused by smoke inhalation or asphyxiation, with many attributed to "firefighters going deep into large structures, becoming caught, lost, or disoriented, and then subsequently running out of breathing air before being able to exit," the proposal states. "While modern practice is for firefighters to practice 'air management' or allocate enough breathing air for entry, work, and exit, many find maintaining situational awareness difficult. Many still rely on the indicator alarm to tell them to begin their exit, which is problematic because fire departments are finding that allotting 20-25 percent of the breathing air supply to exit does not allow enough time for escape from a large structure. If the firefighter becomes disoriented in the smoke, rescuers will have very little time to bring the individual out of the building unharmed."

Product Showcase

  • Glove Guard® Clip

    Safety should never be compromised, especially when it comes to proper glove usage. The Glove Guard® clip enhances safety by encouraging employees to keep their gloves with them at all times. This reduces the risk of accidents and injuries on the job. By ensuring everyone has their gloves readily available, we help promote a culture of safety and efficiency. The Glove Guard® clip is designed to withstand the toughest work environments. Constructed from robust materials made in the USA, it can endure extreme conditions, including harsh weather, and rigorous activities. Read More

  • Magid® D-ROC® GPD412 21G Ultra-Thin Polyurethane Palm Coated Work Gloves

    Magid’s 21G line is more than just a 21-gauge glove, it’s a revolutionary knitting technology paired with an advanced selection of innovative fibers to create the ultimate in lightweight cut protection. The latest offering in our 21G line provides ANSI A4 cut resistance with unparalleled dexterity and extreme comfort that no other 21-gauge glove on the market can offer! Read More

  • Safety Shower Test Cart

    The Safety Shower Test Cart speeds up and simplifies emergency shower tests, ensures you stay in compliance with OSHA regulations, and significantly reduces testing costs. With 7 unique features, the cart makes testing easy, effective, and efficient. You can test water clarity, flow, temperature, and spread—all at the same time! Most safety shower testing kits create a mess, take too much time to use, and don't fully help you stay in compliance with OSHA & ANSI standards. Transform the way you test emergency showers with Green Gobbler Safety. Read More

Featured

Artificial Intelligence