CSB: Flash Fires at Hoeganaes Plant were Preventable

The CSB investigation found that significant amounts of fine iron powder had accumulated over time at the Hoeganaes facility, and that while the company knew from its own testing and experience with flash fires in the plant that the dust was combustible, it did not take the necessary action to reduce the hazards through engineering controls and basic housekeeping.

The U.S. Chemical Safety Board on Thursday released its final report on three accidents that occurred in 2011 at the Hoeganaes powdered metals plant in Gallatin, Tenn. Flash fires and an explosion killed a total of five workers and injured three others.

The CSB investigation found that significant amounts of fine iron powder had accumulated over time at the Hoeganaes facility, and that while the company knew from its own testing and experience with flash fires in the plant that the dust was combustible, it did not take the necessary action to reduce the hazards through engineering controls and basic housekeeping. The investigation also found that Hoeganaes did not institute procedures such as combustible gas monitoring or provide training for employees on avoiding flammable gas fires and explosions.

The Board issued several safety recommendations, including that OSHA develop and publish a proposed combustible dust standard within one year and ensure that the new standard includes coverage for combustible iron and steel powders.

CSB Chairperson Rafael Moure Eraso said, “The three accidents at the Hoeganaes facility were entirely preventable. Despite evidence released by the CSB and information that Hoeganaes had in its possession even before the first accident in January 2011, the company did not institute adequate dust control or housekeeping measures. Dust fires and explosions continue to claim lives and destroy property in many industries. More must be done to control this hazard. No more lives should be lost from these preventable accidents.”

CSB also released a safety video entitled “Iron in the Fire,” which features computer animations depicting each accident.

The first of the three 2011 accidents at the Hoeganaes plant occurred on Jan. 31 when fine particles of iron dust ignited while a maintenance mechanic and an electrician were troubleshooting a problem with a bucket elevator. Both employees suffered burns and later died from their injuries. The CSB investigation into that accident was underway when on March 29, a similar flash fire burned another Hoeganaes worker.

At a news conference in Tennessee on May 11, 2011, CSB released laboratory test results on dust samples taken from the plant after the second accident. The testing demonstrated the combustibility of even small amounts of the iron dust when dispersed in air in the presence of an ignition source.

Sixteen days after CSB released those test results, on May 27, a hydrogen explosion erupted in the plant after the gas began leaking from a corroded furnace pipe. The blast shook loose iron dust accumulations from the upper reaches of the building, which ignited and rained down on workers. The explosion and ensuing fire killed three workers and injured two others. CSB found that the company did not require atmospheric testing for hydrogen or other explosive gases.

Investigator Johnnie Banks said, “When the Hoeganaes facility was built more than thirty years ago it was not designed according to good practice guidelines on combustible dust, such as those set forth by the National Fire Protection Association, or NFPA. And during its decades of operation, it was never redesigned to address the serious dust hazard. The CSB is recommending that Hoeganaes conduct periodic audits to ensure compliance with the appropriate NFPA codes and standards.”

The CSB report notes that engineering controls, such as enclosing conveyors and installing properly designed dust collection equipment, are the best ways to prevent dust accumulations. CSB investigators found that the plant’s powder handling equipment was not adequately sealed.

CSB is recommending that OSHA develop and publish a proposed combustible dust standard within one year—ensuring that the new standard includes coverage for combustible iron and steel powders. The Board is also recommending that the Tennessee Occupational Safety and Health Administration target facilities that generate metal dust.

CSB is also recommending that the International Code Council, which sets safety standards that may be adopted by state and local governments, revise its standards to require mandatory compliance and enforcement with the detailed requirements of NFPA standards related to preventing accumulation of combustible dust in workplaces.

Product Showcase

  • SlateSafety BAND V2

    SlateSafety BAND V2

    SlateSafety's BAND V2 is the most rugged, easy-to-use connected safety wearable to help keep your workforce safe and help prevent heat stress. Worn on the upper arm, this smart PPE device works in tandem with the SlateSafety V2 system and the optional BEACON V2 environmental monitor. It includes comprehensive, enterprise-grade software that provides configurable alert thresholds, real-time alerts, data, and insights into your safety program's performance all while ensuring your data is secure and protected. Try it free for 30 days. 3