A study of nearly 13,000 rescue workers from the Fire Department of the City of New York (FDNY) shows that the significant proportion who suffered acute lung damage after exposure to World Trade Center (WTC) dust have not recovered normal lung function in the years since the Sept. 11, 2001 terrorist attacks.

This seven-year study, with almost 62,000 individual measurements, is the largest longitudinal study ever reported of occupational influences on lung function. It is the only group of WTC workers for which pre-9/11 lung function measurements were available. The study, led by researchers at Albert Einstein College of Medicine of Yeshiva University and Montefiore Medical Center, in collaboration with FDNY, appears in the April 8, 2010 print edition of The New England Journal of Medicine.

"This exposure at Ground Zero was so unique that no one could have predicted the impact on lung function. We demonstrated dramatic decline in lung function, mostly in the first 6 months after 9/11, and these declines persisted with little or no meaningful recovery of lung function among FDNY rescue workers (firefighters and emergency medical service workers) over the next six-and-a-half years," said David Prezant, M.D., professor of medicine at Einstein and senior author of the study. Prezant is also an attending physician in the pulmonary medicine division at Montefiore Medical Center, the University Hospital and Academic Medical Center for Einstein, the chief medical officer of the FDNY, Office of Medical Affairs, and the co-director of the FDNY WTC Medical Programs.

For Prezant and his team, the critical mission remains identifying the individuals most affected and providing them with treatment to improve their quality of life and prevent further declines in lung function.

The current research follows up on a previous 2006 study, published in the American Journal of Respiratory and Critical Care Medicine, that assessed lung function one year after the 9/11 attacks. In that study, Prezant and colleagues found that 9/11 FDNY rescue workers suffered substantial loss in lung function in the year following the attacks--more than 12 times the decline in lung function that would be expected to occur with normal aging. The largest decline was observed among workers who arrived at the WTC site the morning of 9/11, when the dust cloud was most intense.

For the present study, the workers evaluated include nearly 92 percent of the 13,954 FDNY firefighters and EMS workers present at the WTC site from Sept. 11-24, 2001. Lung function in these 12,781 individuals was assessed by spirometry testing performed every 12 to 18 months. Spirometry measures the amount of air exhaled in a single breath.

All participants had also been tested pre-9/11, so those spirometric results provided a baseline for assessing lung-function decline. Because the decline was severe and persistent, a substantial proportion of FDNY rescue workers were left with abnormal lung function by the end of this study, September 11, 2008. For example, the proportion of those who never smoked--and whose lung function was below normal--increased over the first year from 3 to 18 percent for firefighters and from 12 to 22 percent for EMS workers, stabilizing at about 13 percent for firefighters and 22 percent for EMS workers by the end of the seven-year study. ("Below normal" is defined as less than that achieved by 95 percent of normal nonsmokers of similar age, gender, and height.)

"Previous studies have indicated that the effects of firefighting on lung function are mild and reversible," said lead author Thomas Aldrich, M.D., professor of medicine at Einstein and an attending physician in the pulmonary medicine division at Montefiore. "The difference seems to be that the workers in our study population experienced repeated daily exposures to much higher concentrations of airborne particulates (solid particles suspended in the air) and gaseous chemicals."

Aldrich suggests that the lack of long-term recovery among the 9/11 rescue workers may be due to several factors: the unusual nature of the dust cloud itself--which was thick with particulates, inhaled pulverized material from the collapse of the towers, and smoke from fires that continued to burn until mid-December.

"All smoke contains particulates, but not at the density seen in the WTC collapse, especially if you were at the site during the first two or three days or for long durations thereafter," Aldrich said. "In a normal fire, you don't get enveloped in a particulate cloud so thick that you can’t even see through it."

The paper, titled "Lung Function in Rescue Workers at the World Trade Center after 7 Years," appears in the April 7 online edition and April 8 print edition of The New England Journal of Medicine. The study was funded by the National Institute of Occupational Safety and Health.

Other Einstein researchers who contributed to the study include Charles Hall, Ph.D.; Hillel Cohen, Dr.P.H.; and Mayris Webber, Dr.P.H. Other contributors include Fairouz Al-Othman, M.D., Rachel Zeig-Owens, M.P.H., and Vasilios Christodoulou, B.A., of Montefiore Medical Center; Jackson Gustave, M.P.H., Kaitlyn Cosenza, B.A., Lara Glass, M.P.H., and Kerry Kelly, M.D., of the Fire Department of the City of New York, Bureau of Health Services; and Michael Weiden, M.D., of the New York University School of Medicine, Pulmonary Division and the Fire Department of the City of New York, Bureau of Health Services.

Product Showcase

  • SECUPRO MARTEGO

    FOR HIGHEST DEMANDS. A cutting tool in which function and design go hand in hand. Meet the SECUPRO MARTEGO, our prize-winning squeeze-grip safety knife with fully automatic retractable blade for safety. • Ergonomically friendly trigger mechanism to engage the blade • Durable body made of aluminum • Safer alternative to fixed blade utility knives for general cutting tasks • 9 mm Cutting depth • Easy, tool free blade change Dimensions: L 6.10" L x 0.71" W x 1.91" H Weight: 3.70 oz Cutting Depth: 9 mm Read More

  • Glove Guard® Clip

    Safety should never be compromised, especially when it comes to proper glove usage. The Glove Guard® clip enhances safety by encouraging employees to keep their gloves with them at all times. This reduces the risk of accidents and injuries on the job. By ensuring everyone has their gloves readily available, we help promote a culture of safety and efficiency. The Glove Guard® clip is designed to withstand the toughest work environments. Constructed from robust materials made in the USA, it can endure extreme conditions, including harsh weather, and rigorous activities. Read More

  • Matrix's OmniPro Vision AI Collision Avoidance System

    OmniPro Vision AI is a state-of-the-art collision avoidance system that features NIOSH award-winning Visual Artificial Intelligence (AI) technology. This highly accurate, powerful system identifies and alerts on pedestrians, vehicles and specified objects, ensuring safer facilities, mining operations and industrial sites. With its web-based cloud application, OmniPro Vision AI also logs and analyzes a wide range of data related to zone breach notifications. Operating without needing personal wearable devices or tags, OmniPro has visual and audible zone breach alerts for both operators and pedestrians. Read More

Featured

Artificial Intelligence