Coarse Air Pollution Not Linked to Hospital Admission for Respiratory Disease

A study in the May 14 issue of JAMA reports that it found no statistically significant association between exposure to coarse particulate matter air pollution--such as from agricultural activities, windblown dust, and mechanical grinding--and emergency hospital admissions for respiratory and cardiovascular diseases among Medicare patients.

Health risks of fine particulate matter of 2.5 µm or less in aerodynamic diameter (PM2.5) have been studied extensively over the last decade, providing strong evidence of an association for a higher risk of illness and death. Evidence concerning the health risks of the coarse particulate matter of greater than 2.5 µm and 10 µm or less in aerodynamic diameter (PM10-2.5) is limited, and findings have been mixed, according to background information in the article. Coarse particles would likely deposit in the upper and larger airways, the study said. Particles in the PM2.5 size range, which are more likely to result from combustion processes, can reach the smaller airways and air sacs within the lungs.

Roger D. Peng, Ph.D., of the Johns Hopkins Bloomberg School of Public Health, Baltimore, and his colleagues estimated the risk of hospital admissions for cardiovascular and respiratory diseases associated with PM10-2.5 exposure by using a database assembled for 108 U.S. counties (population larger than 200,000 in 2000) with daily cardiovascular and respiratory disease admission rates, temperature, and dew-point temperature and monitoring of PM10-2.5 and PM2.5 concentrations. Admission rates were constructed from the Medicare National Claims History Files, for a study population of approximately 12 million Medicare enrollees living on average nine miles from pairs of PM10 and PM2.5 monitors.

There were 3.7 million cardiovascular disease and 1.4 million respiratory disease admissions from January 1999 through December 2005. A 10-µg/m3 increase in PM10-2.5 was associated with a 0.36 percent increase in cardiovascular disease admissions on the same day and this association was statistically significant. However, when adjusted for PM2.5, this association was no longer statistically significant (0.25 percent). A 10-µg/m3 increase in PM10-2.5 was associated with a nonstatistically significant unadjusted 0.33 percent increase in respiratory disease admissions and a nonstatistically significant 0.26 percent increase in respiratory disease admissions when adjusted for PM2.5. The unadjusted associations of PM2.5 with cardiovascular and respiratory disease admissions were 0.71 percent for same-day exposure and 0.44 percent for exposure 2 days before hospital admission.

The study found no statistically significant differences in the regional average effects of PM10-2.5 for either outcome. Also, there were no significant associations of PM10-2.5 or PM2.5 and cause-specific cardiovascular disease and respiratory disease outcomes.

The study states that, "The National Ambient Air Quality Standard (NAAQS) for particulate matter proposed by the U.S. Environmental Protection Agency (EPA) in 2005 would have replaced the daily PM10 standard with a daily PM10-2.5 standard, but that proposed standard was not retained in the final proposal because of a need for further evidence. Currently, national evidence concerning the health risks of short-term exposure to PM10-2.5 is limited, although there is long-standing recognition of how size influences patterns of deposition within the respiratory tract. We did not find statistically significant associations between same day PM10-2.5 concentration and emergency hospital admissions for cardiovascular or respiratory diseases when we adjusted for PM2.5."

For more informations, visit http://jama.ama-assn.org.

Product Showcase

  • SECUPRO MARTEGO

    FOR HIGHEST DEMANDS. A cutting tool in which function and design go hand in hand. Meet the SECUPRO MARTEGO, our prize-winning squeeze-grip safety knife with fully automatic retractable blade for safety. • Ergonomically friendly trigger mechanism to engage the blade • Durable body made of aluminum • Safer alternative to fixed blade utility knives for general cutting tasks • 9 mm Cutting depth • Easy, tool free blade change Dimensions: L 6.10" L x 0.71" W x 1.91" H Weight: 3.70 oz Cutting Depth: 9 mm Read More

  • SwabTek® Cannabis Test Kit

    The SwabTek® Cannabis Test Kit is a single-use spot test designed for use in screening for cannabis compounds in any sample type or on any surface. The test is capable of identifying the presumed presence of cannabinoids in very small quantities, with a level of detection as little as 6 μg in mass. Learn more about the SwabTek® Cannabis Test Kit and the rest of SwabTek surface drug testing solutions through the webinar titled "Everything You Want To Know About Surface Testing" Read More

  • Glove Guard® Clip

    Safety should never be compromised, especially when it comes to proper glove usage. The Glove Guard® clip enhances safety by encouraging employees to keep their gloves with them at all times. This reduces the risk of accidents and injuries on the job. By ensuring everyone has their gloves readily available, we help promote a culture of safety and efficiency. The Glove Guard® clip is designed to withstand the toughest work environments. Constructed from robust materials made in the USA, it can endure extreme conditions, including harsh weather, and rigorous activities. Read More

Featured

Artificial Intelligence

Webinars