CSB Investigation Pinpoints Cause of Horsehead Zinc Explosion

Reused sump at the bottom of a ceramic zinc distillation column was partially blocked, allowing superheated liquid zine to build up in the colum, which "explosively decompressed," killing two employees in July 2010.

The U.S. Chemical Safety and Hazard Investigation Board (CSB) last week released the results of its investigation into an explosion and fire on July 22, 2010, at the Horsehead Corporation zinc refinery in Monaca, Pa, an incident in which two of the company's operators died. The explosion likely resulted from a buildup of superheated liquid zinc inside a ceramic zinc distillation column, which then "explosively decompressed" and ignited, killing employees James Taylor and Corey Keller. A sump at the bottom of the column had not been replaced when the column was rebuilt a month earlier, and the problematic sump became partially blocked, allowing the buildup, according to CSB, which reported there were multiple zinc distillation columns operating in the refinery when the explosion occurred and released a large amount of zinc vapor, which at high temperatures combusts spontaneously in the presence of air. The two victims had been performing unrelated maintenance work on another nearby column when the explosion and fire occurred; a third operator was seriously injured and could not return to work.

Seeking to explain the underlying cause, CSB contracted last fall with an internationally known zinc distillation expert, William Hunter of the United Kingdom, to review of the evidence file, including witness interviews, company documents, site photographs, surveillance videos, lab test results, and data from the facility's distributed control system. CSB released Hunter's 57-page report after sharing draft versions of it with Horsehead and the United Steelworkers union that represented Horsehead workers in Monaca.

The refinery was closed and dismantled after the 2010 incident, according to CSB, which added that the "New Jersey" distillation-based zinc refining method used there was first developed in the 1920s and used for decades in Monaca, but is no longer practiced anywhere in the United States, although it is overseas, notably in China. "Although this particular zinc technology has ceased being used in the U.S., we felt it was important to finally determine why this tragedy occurred," said CSB Chairperson Dr. Rafael Moure-Eraso. "Our hope is that this will at last provide a measure of closure to family members, as well as inform the safety efforts of overseas companies using similar production methods."

The explosion occurred only 12 days after the construction and startup of Column B, which operated at more than 1,600° F and normally has only small amounts of liquid metals in its various trays. Hunter's analysis said flooding of the column creates a very hazardous condition, which is likely what occurred on July 22, 2010. "Under extreme pressure the tray wall(s) eventually failed, releasing a large volume of zinc vapor and superheated zinc that would flash to vapor, and this pressure pushed out the combustion chamber blast panels," Hunter's report stated. "The zinc spray and vapor now had access to large amounts of workplace air and this created a massive zinc flame across the workplace."

The previous column that used the same sump had to be shut down prematurely due to sump drainage problems, the analysis found, and problems with the sump were observed during the July 2010 startup of the new Column B. Over at least an hour preceding the explosion, DCS data indicate a gradual warming at the base of Column B, as liquid zinc likely built up and flooded the lower trays, while vapor flow to the overhead condenser ceased. "Ten minutes before the explosion, an alarm sounded in the control room due to a high rate of temperature change in the column waste gases, as zinc likely began leaking out of the column into the combustion chamber, but by then it was probably too late to avert an explosion, according to the analysis. Control room operators responded to the alarm by cutting the flow of fuel gas to Column B but did not reduce the flow of zinc into the column. The unsafe condition of Column B was not understood, and operators inside the building were not warned of the imminent danger," CSB reported.

His report noted New Jersey-type zinc distillation columns have been involved in serious incidents around the world. In 1993 and 1994, two column explosions at a former French zinc factory killed a total of 11 workers, and an international committee of experts who investigated them identified up to 10 other major incidents at other sites attributable to sump drainage problems. The Monaca facility had five documented column explosions prior to 2010, but none of them involved fatalities, according to the report.

Product Showcase

  • SECUPRO MARTEGO

    FOR HIGHEST DEMANDS. A cutting tool in which function and design go hand in hand. Meet the SECUPRO MARTEGO, our prize-winning squeeze-grip safety knife with fully automatic retractable blade for safety. • Ergonomically friendly trigger mechanism to engage the blade • Durable body made of aluminum • Safer alternative to fixed blade utility knives for general cutting tasks • 9 mm Cutting depth • Easy, tool free blade change Dimensions: L 6.10" L x 0.71" W x 1.91" H Weight: 3.70 oz Cutting Depth: 9 mm Read More

  • Kestrel 5400 Heat Stress Tracker WBGT Monitoring for Workplace Safety

    Ensure safety with the Kestrel® 5400 Heat Stress Tracker, the go-to choice for safety professionals and endorsed by the Heat Safety & Performance Coalition. This robust, waterless WBGT meter is ideal for both indoor and outdoor environments, offering advanced monitoring and data logging essential for OSHA compliance. It features pre-programmed ACGIH guidelines and alert settings to quickly signal critical conditions. Integrated with the cloud-based Ambient Weather Network, the 5400 allows managers to view, track, and log job site conditions remotely, ensuring constant awareness of potential hazards. Its capability for real-time mobile alerts and remote data access promotes proactive safety management and workplace protection, solidifying its role as a crucial tool in industrial hygiene. Read More

  • NoiseCHEK Personal Noise Dosimeter

    SKC NoiseCHEK is the easiest-to-use dosimeter available! Designed specifically for OEHS professionals, SKC NoiseCHEK offers the easiest operation and accurate noise measurements. Everything you need is right in your palm. Pair Bluetooth models to your mobile devices and monitor workers remotely with the SmartWave dB app without interrupting workflow. Careful design features like a locking windscreen, sturdy clip, large front-lit display, bright status LEDs, and more make NoiseCHEK the top choice in noise dosimeters. Demo NoiseCHEK at AIHA Connect Booth 1003. Read More

Featured

Artificial Intelligence