Ali Rangwala, assistant professor of fire protection engineering at Worcester Polytechnic Institute

WPI Prof Receives NSF Award to Study Physics of Dust Explosions

Although dust buildup is among the most serious and common fire and explosion hazards in a range of industries, little is known about how dust ignites or how dust explosions propagate, according to Ali Rangwala, assistant professor of fire protection engineering at Worcester Polytechnic Institute in Worcester, Mass. With the help of the National Science Foundation, Rangwala is hoping to unveil the mysteries.

WPI, one of the nation's first engineering and technology universities, announced that Rangwala has received a five-year, $429,000 CAREER Award from NSF, which developed the grant program for faculty members who are at or near the beginning of their careers. Rangwala will use the funds to research dust layer ignition and flame propagation in dust clouds.

While a number of studies of dust explosions have been conducted over the years, none have been aimed at developing a fundamental understanding of the physics of the phenomenon, Rangwala said. In particular, his study will examine how factors such as the size of dust particles, their chemical make-up, the density of dust clouds, and the heat of combustion (the heat released when a substance burns) affect how likely a dust cloud is to ignite, how rapidly it will burn, and how the fire will spread. Other studies will look at the risks associated with dust as it accumulates in thick layers, particularly in corners. Fires can smolder in dust layers for long periods before erupting, often triggering dust explosions.

The importance of this line of study was made evident to the nation in February 2008 when a massive explosion and fire at the Imperial Sugar Co. plant in Port Wentworth, Ga., took 13 lives and injured 40 others. The culprit was dust. Shaken loose by employees pounding on a silo, a cloud of sugar dust drifted toward a moving conveyor belt, which ignited it. The incident highlighted the extreme danger posed by dust that accumulates in many industrial settings, from coal mines, to saw mills, to factories that make everything from plastics to corn-based ethanol to pharmaceuticals.

Rangwala will study dust combustion with small-scale laboratory experiments using novel experimental designs and, in many cases, equipment developed for this study. "We will be creating a new experimental platform here at WPI that will allow us to look at the mechanics of fire phenomenon," he said. "We will be carrying out experiments that have never been attempted before. The practice of conducting small-scale lab experiments and then scaling up from the results is common in fields like aeronautical and civil engineering, but is new to fire protection engineering."

Rangwala said he hopes the results of his experiments will become the basis for more robust models that will help assess and predict the risks associated with dust accumulation and ultimately lead to better and safer practices for the design and maintenance of industrial facilities that generate dust. "I am also hopeful that this research program will help effect a shift away from the empirical, engineering-based models commonly used in fire safety and engineering toward models derived from analysis and experimentation," he said.

WPI said that in addition to funding his research, the CAREER Award will enable Rangwala to promote interest in careers in fire protection engineering and fire research through educational programs at the college and pre-college levels. Working with WPI's Office of K-12 Outreach Programs, he will develop a three-week summer program in which high school students will explore fire safety problems and learn about fire and explosion phenomenon through laboratory exercises. At the college level, he will develop an undergraduate project center at the University of Edinburgh in the United Kingdom, which is recognized internationally for its work in fire protection engineering. There, students from WPI, Edinburgh, and universities in France and India will cooperate on cutting-edge projects in fire research.

Product Showcase

  • Full Line of Defense Against Combustible Dust Nilfisk

    Nilfisk provides a comprehensive range of industrial vacuums meticulously crafted to adhere to NFPA 652 housekeeping standards, essential for gathering combustible dust in Class I, Group D, and Class II, Groups E, F & G environments or non-classified settings. Our pneumatic vacuums are meticulously engineered to fulfill safety criteria for deployment in hazardous surroundings. Leveraging advanced filtration technology, Nilfisk ensures the secure capture of combustible materials scattered throughout your facility, ranging from fuels, solvents, and metal dust to flour, sugar, and pharmaceutical powders. Read More

  • The MGC Simple Plus

    The MGC Simple Plus is a simple-to-use, portable multi gas detector that runs continuously for three years without being recharged or routinely calibrated after its initial charge and calibration during manufacturing. The detector reliably tests a worksite’s atmosphere for hydrogen sulfide, carbon monoxide, oxygen and combustible gases (LEL). Its durability enables the detector to withstand the harshest treatment and environments, hence earning it an IP 68 rating. The MGC Simple Plus is also compatible with a variety of accessories, such as the GCT External Pump. Visit gascliptech.com for more information. Read More

  • SECUPRO MARTEGO

    FOR HIGHEST DEMANDS. A cutting tool in which function and design go hand in hand. Meet the SECUPRO MARTEGO, our prize-winning squeeze-grip safety knife with fully automatic retractable blade for safety. • Ergonomically friendly trigger mechanism to engage the blade • Durable body made of aluminum • Safer alternative to fixed blade utility knives for general cutting tasks • 9 mm Cutting depth • Easy, tool free blade change Dimensions: L 6.10" L x 0.71" W x 1.91" H Weight: 3.70 oz Cutting Depth: 9 mm Read More

Featured

Artificial Intelligence

Webinars