Report: Out-of-Hospital Cardiac Arrest Survival Rate Unchanged in 30 Years

The chance of surviving an out-of-hospital cardiac arrest has not improved since the 1950s, according to a report by the University of Michigan Health System. The analysis shows only 7.6 percent of victims survive an out-of-hospital cardiac arrest, a number that has not changed significantly in almost 30 years.

It's a dismal trend considering enormous spending on heart research, new emergency care protocols, and the advent of new drugs and devices such as defibrillators. Each year, 166,000 people experience cardiac arrest--an event during which the heart stops beating--away from a hospital.

Physicians report in the current issue of Circulation: Cardiovascular Quality and Outcomes that there are some key factors that can make a difference in saving lives when cardiac arrest happens at home, a hotel, restaurant, or workplace.

"Our study shows that patients with a heart rhythm that can be shocked, or who have bystander CPR or a pulse restored at the scene have a much greater chance of survival," said lead author Comilla Sasson, M.D., a Robert Wood Johnson Scholar and emergency medicine physician at the U-M Health System.

Although half of cardiac arrests are witnessed by a bystander, according to the study, only 32 percent, or about one in every three people, is receiving bystander CPR.

This is the first study that looks at the associations between five clinical variables and overall survival from an out-of-hospital cardiac arrest. The variables studied include: witnessed by emergency medical services provider; bystander CPR; types of heart rhythm--asystole (motionless) vs. ventricular fibrillation (rapid or twitching); and return of spontaneous circulation.

Researchers evaluated data on 142,740 patients from 79 studies published internationally between January 1950 and August 2008.

Here's what researchers found:

  • Of the more than 140,000 patients, only 23.8 percent survived to hospital admission, and 7.6 percent, or about one in 10 people, lived to be discharged from the hospital.
  • Cardiac arrest victims who received CPR from a bystander or an emergency medical services provider, and those who had a shockable heart rhythm, referred to as ventricular fibrillation, were more likely to survive.
  • The strongest predictor of survival was a return of spontaneous circulation, meaning a pulse was restored at the scene. Among them, 15.5 percent (in low-performing EMS systems) to 33.6 percent (in high performing EMS systems) survived.

"Increasing bystander CPR rates, increasing the awareness and use of devices to shock the heart, and keeping paramedics on scene until they restore a person's pulse needs to occur if we are ever going to change our dismal survival rate," said Sasson, noting that places like Seattle, which has the highest rates of cardiac arrest survival in the country, are doing these three basic things exceptionally well. "We can learn a lot from that emergency response system."

The lack of progress in survival across the United States and abroad may be linked to an aging population; a lower number of people who are found in a shockable rhythm, which is associated with the highest chance of survival; and longer EMS drives due to the increasing size of cities and traffic congestion, authors wrote.

While the overall rate of out-of-hospital cardiac arrest survival has not improved, the field of cardiac and cerebral resuscitation is rapidly evolving.

Most of the studies in the analysis were conducted before the advent of therapeutic hypothermia, a body cooling treatment that has shown to benefit resuscitated patients. U-M C.S. Mott Children's Hospital is leading a clinical trial to evaluate therapeutic hypothermia to prevent brain damage in children who have cardiac arrest.

Studies did not distinguish between patients treated with traditional CPR and those cared for under new American Heart Association guidelines for CPR which emphasizes chest compressions over mouth-to-mouth resuscitation.

Additional authors are: Mary A.M. Rogers, Ph.D., University of Michigan Department of Internal Medicine; Jason Dahl, M.D., University of Rochester, Rochester, N.Y.; and Arthur L. Kellerman, M.D., MPH, Emory University, Atlanta.

Product Showcase

  • Glove Guard® Clip

    Safety should never be compromised, especially when it comes to proper glove usage. The Glove Guard® clip enhances safety by encouraging employees to keep their gloves with them at all times. This reduces the risk of accidents and injuries on the job. By ensuring everyone has their gloves readily available, we help promote a culture of safety and efficiency. The Glove Guard® clip is designed to withstand the toughest work environments. Constructed from robust materials made in the USA, it can endure extreme conditions, including harsh weather, and rigorous activities. 3

  • Kestrel 5400 Heat Stress Tracker WBGT Monitoring for Workplace Safety

    Ensure safety with the Kestrel® 5400 Heat Stress Tracker, the go-to choice for safety professionals and endorsed by the Heat Safety & Performance Coalition. This robust, waterless WBGT meter is ideal for both indoor and outdoor environments, offering advanced monitoring and data logging essential for OSHA compliance. It features pre-programmed ACGIH guidelines and alert settings to quickly signal critical conditions. Integrated with the cloud-based Ambient Weather Network, the 5400 allows managers to view, track, and log job site conditions remotely, ensuring constant awareness of potential hazards. Its capability for real-time mobile alerts and remote data access promotes proactive safety management and workplace protection, solidifying its role as a crucial tool in industrial hygiene. 3

  • The MGC Simple Plus

    The MGC Simple Plus is a simple-to-use, portable multi gas detector that runs continuously for three years without being recharged or routinely calibrated after its initial charge and calibration during manufacturing. The detector reliably tests a worksite’s atmosphere for hydrogen sulfide, carbon monoxide, oxygen and combustible gases (LEL). Its durability enables the detector to withstand the harshest treatment and environments, hence earning it an IP 68 rating. The MGC Simple Plus is also compatible with a variety of accessories, such as the GCT External Pump. Visit gascliptech.com for more information. 3