Aspirating Smoke Detection (ASD) is designed for reliability and is capable of customization to minimize false alarms and maintenance, while increasing safety.

Early smoke detection is often critical to quickly suppress fires. In some settings such as manufacturing facilities, voluminous dust and particulates from various products and processes can be confused with smoke by most traditional, or passive, smoke detection systems, triggering ongoing alarms. Resolving these alarms often requires excessive troubleshooting and maintenance to keep the system functional. When this is the case, prevalent nuisance alarms may compromise safety.

Although most manufacturing facilities deal with some level of dust, there is no more challenging environment that illustrates the need for advanced detection systems that accurately distinguish dust from smoke than inside a dust collection system. Fortunately, even within this dustiest of environments, aspirating smoke detection (ASD) technology can be an effective option.

Advanced ASD systems can significantly reduce false alarms and maintenance while increasing safety by detecting smoke at the earliest possible stage via numerous sampling points. The process draws in air through durable piping and analyzes it using sophisticated laser-based technology, imaging, and photodiodes technology. Continuous air sampling drawn from the protected area through the pipe network to the sensing unit provides the fastest possible smoke detection rates. In doing so, the system effectively distinguishes between actual smoke and dust or particulates to all but eliminate nuisance alarms. This core technology has been used for decades in sensitive applications such as cleanrooms and data centers where early smoke detection is critical.

Although these systems are quite flexible, many facilities use different processes and materials in varying volumes with unique facility layouts. It is important to consider engaging a partner that can design the system to fit a facility’s specific needs.

Extreme Dust: A Smoke Detection and Maintenance Challenge

In a manufacturing process at an aluminum tubing provider, a fine hot zinc powder is spray coated onto tubing in a spray booth area. The excess powder is then directed to a dust collection system consisting of large-diameter ducting and paper-based filter media before clean air is vented outdoors.

The zinc dust accumulates quickly and abundantly inside the ducting and can easily overwhelm the filters. This required excessive inspection and frequent maintenance to keep the system fully operational, according to Mike Angstadt, president of Palmetto, Florida-based Flagship Fire, Inc., whose company was hired to improve the system’s fire safety. The company provides special hazards fire suppression, control and detection solutions for unique, high value industrial assets.

Joseph Albert, project manager at Flagship Fire, Inc. notes, “When technicians would do routine maintenance every few months on sections of ducting, they would bang the sections with a rubber mallet to remove several inches of zinc dust that accumulated inside of this duct work.”

According to Angstadt, the dust laden, paper-based filter media would also periodically catch fire when ignited by a stray spark. The plant tasked Flagship Fire to improve smoke detection and fire safety within the dust collection system.

“Even though the deflagration index of the dust is low enough that providing explosion protection is not required, the plant sought greater safety with early smoke detection and fire suppression inside the dust collection system,” says Angstadt.

As a solution, Flagship Fire specified an ASD system. The ASD system draws air samples in a continuous process through holes in durable industrial pipe mounted along the walls and ceiling. The ASD system analyzes the air in a flair detection chamber that uses a short wavelength laser, a CMOS imager and multiple photodiodes that can distinguish between smoke and dust, minimizing false alarms. The system is cross zoned with thermal detectors inside the dust collection filter area.

“With this arrangement, plant operators can manually discharge the high-pressure, CO2 fire suppression agent as needed, or if an incident occurred after hours and no one was present, the plant’s VESDA system, cross zoned with a thermal device, will automatically discharge to suppress the fire,” says Angstadt.

Some minor adjustments were also required to increase system reliability. Since the ASD system draws in air, it does not require direct airflow into the analyzer. In fact, too much airflow could affect the results, so Flagship Fire angled the ASD system air sampling points away from the most voluminous air flow sources. 

According to Angstadt, the ASD system has performed well since the installation, in conjunction with the thermal device and automatic CO2 fire suppression system. This arrangement has not only minimized false alarms caused by particulates in the dust collection system but also helped improve plant safety by enabling smoke detection at the earliest possible stages of a fire.

Download Center

  • Safety Metrics Guide

    Is your company leveraging its safety data and analytics to maintain a safe workplace? With so much data available, where do you start? This downloadable guide will give you insight on helpful key performance indicators (KPIs) you should track for your safety program.

  • Job Hazard Analysis Guide

    This guide includes details on how to conduct a thorough Job Hazard Analysis, and it's based directly on an OSHA publication for conducting JHAs. Learn how to identify potential hazards associated with each task of a job and set controls to mitigate hazard risks.

  • A Guide to Practicing “New Safety”

    Learn from safety professionals from around the world as they share their perspectives on various “new views” of safety, including Safety Differently, Safety-II, No Safety, Human and Organizational Performance (HOP), Resilience Engineering, and more in this helpful guide.

  • Lone Worker Safety Guide

    As organizations digitalize and remote operations become more commonplace, the number of lone workers is on the rise. These employees are at increased risk for unaddressed workplace accidents or emergencies. This guide was created to help employers better understand common lone worker risks and solutions for lone worker risk mitigation and incident prevention.

  • EHS Software Buyer's Guide

    Learn the keys to staying organized, staying sharp, and staying one step ahead on all things safety. This buyer’s guide is designed for you to use in your search for the safety management solution that best suits your company’s needs.

  • Vector Solutions

Featured Whitepaper

OH&S Digital Edition

  • OHS Magazine Digital Edition - July August 2022

    July / August 2022

    Featuring:

    • CONFINED SPACES
      Specific PPE is Needed for Entry and Exit
    • HAZARD COMMUNICATION
      Three Quick Steps to Better HazCom Training
    • GAS DETECTION
      Building a Chemical Emergency Toolkit
    • RESPIRATORY PROTECTION
      The Last Line of Defense
    View This Issue