$378,620 in Fines Issued to Wisconsin Wood Firm for Willful Violations

Northeastern Wisconsin Wood Products was first inspected by OSHA in 2006 and issued eight citations. A follow-up inspection in 2007 found that most of the originally cited hazards remained unabated.

OSHA has cited Northeastern Wisconsin Wood Products in Pound, Wis., for a total of 18 alleged health and safety, including 13 willful, violations. The company is facing $378,620 in proposed penalties following a January inspection.

"Northeastern Wisconsin Wood Products has a history of failing to comply with OSHA standards. The company has yet to abate many violations cited in a previous inspection," said Michael Connors, OSHA's regional administrator in Chicago. "When employers knowingly ignore safety and health requirements, they are unduly placing their workers at risk for illnesses and injuries, and that is unacceptable."

Northeastern Wisconsin Wood Products was first inspected by OSHA in 2006 and issued eight citations. A follow-up inspection in 2007 found that most of the originally cited hazards remained unabated. Following the May 2010 issuance of a secretary of labor petition for summary enforcement, the company was given 30 days to work with a Wisconsin state consultation service to abate the violations. The consultation service is alleged to have ended the abatement process due to a lack of cooperation by the company. Many of the originally cited violations once again were cited during the January 2011 inspection.

Five willful health violations involve failing to implement a hearing conservation program for employees whose noise exposure exceeded 85 decibels, perform and certify a hazard assessment of the workplace, develop and implement a hazard communication program to include training for employees, maintain copies of material data sheets, and provide appropriate eye protection for workers. Additionally, the company allowed unsanitary conditions to pose serious fire and explosion hazards by letting sawdust accumulate in a pile of approximately 4 feet by the outer wall and several inches on horizontal surfaces such as pipes, wall supports, and ledges.

Eight willful safety violations involve a lack of machine guarding on belts, pulleys, gears, and band saw blades; a lack of guardrails; unguarded open-sided floors and platforms presenting a fall hazard greater than 4 feet; not using electrical equipment correctly; and not effectively closing openings in boxes and cabinets. Proposed penalties for the 13 willful citations total $360,800.

The company also was cited for one repeat safety violation, with a proposed penalty of $7,920, for failing to provide potable water for drinking.

Three serious safety violations, with proposed penalties of $9,900, include failing to periodically inspect energy control procedures, use group lockout devices and train employees in electrical safety.

One other-than-serious violation, with no monetary penalty, was cited for failing to provide an illuminated exit sign.

Product Showcase

  • HAZ LO HEADLAMPS

    With alkaline or rechargeable options, these safety rated, Class 1, Div. 1 Headlamps provide long runtime with both spot and flood options in the same light. Work safely and avoid trip hazards with flexible hands-free lighting from Streamlight. Read More

  • Preventative Heat Safety

    Dehydration and heat exposure impair physical and cognitive performance. Proper hydration boosts heat stress resilience, but hydration needs are highly individualized and hard to predict across a workforce. Connected Hydration® empowers industrial athletes to stay safe through behavioral interventions, informed by sports science, and equips safety teams with critical insights to anticipate high-risk situations and adapt to evolving environmental factors. Curious about applying the latest in sports science based hydration strategies for industrial athletes? Stop by booth #1112 at AIHA or schedule a free demo today at https://epcr.cc/demo. Read More

  • The MGC Simple Plus

    The MGC Simple Plus is a simple-to-use, portable multi gas detector that runs continuously for three years without being recharged or routinely calibrated after its initial charge and calibration during manufacturing. The detector reliably tests a worksite’s atmosphere for hydrogen sulfide, carbon monoxide, oxygen and combustible gases (LEL). Its durability enables the detector to withstand the harshest treatment and environments, hence earning it an IP 68 rating. The MGC Simple Plus is also compatible with a variety of accessories, such as the GCT External Pump. Visit gascliptech.com for more information. Read More

Featured

Artificial Intelligence

Webinars