How Safe is Your Dust Collector?

Take this quiz and see how many of the top 10 safety practices you are following.

The most basic function of any dust collector is to keep workers and workplaces safer, but not all collectors are created equal from a safety standpoint. Following are 10 tips to help ensure that your dust collection system is as safe as possible. How many of these safety practices are you currently following?

1. Use a dust collector with a higher pressure rating.

When a collector is equipped with an explosion venting or suppression system, as is now required in many applications, vessel strength is an important factor in sizing the explosion protection equipment. A heavy-duty collector, constructed of thicker gauge metal and with a higher pressure rating, will stand up better in the event of a combustible dust explosion. It may also enable you to use a simpler and less costly explosion protection system to comply with NFPA standards.

2. Protect ductwork against explosion hazards.

Even if the dust collector has rugged construction and a properly sized explosion vent, you still need to protect the ductwork that serves the collector. Ducting should be equipped with dampers and valves designed to minimize the risk of explosion within these components. This is a task that is overlooked with surprising frequency.

3. Never store dust in the hopper.

Make sure your dust collector’s hopper is equipped with a device that discharges the dust into a separate drum or storage container after it is pulsed off the filters during the cleaning process. This storage container must be emptied regularly, or dust can back up into the hopper. Dust sitting in a hopper creates a potential fire or explosion risk, and may also affect performance adversely by clogging up the system and preventing the pulse-cleaning system from doing its job.

4. Don’t use a programmable logic controller (PLC) to control pulse-cleaning of filters.

Though PLCs are popular for use with a variety of processes, they are not well-suited to controlling pulse-cleaning of dust collector filter cartridges. Pulse-cleaning relies on very brief (i.e., 150-millisecond), high-energy bursts of compressed air to blow dirt off the filter surfaces. With a PLC, the valve typically opens too slowly for proper pulsing to occur. To optimize cleaning and ensure reliable dust collector operation, use a timer board designed specifically for filter pulsing. The timer board can be used independently or tied into your PLC.

5. Have a written guarantee of emissions performance from the filter supplier.

Sometimes equipment suppliers talk about “removing 99.9 percent of contaminants” of a certain particle size, or they state filter efficiency as a MERV rating. These ratings are useful for comparing performance of different products, but the EPA and OSHA don’t care about percentage efficiency claims: They want to know that emissions will be at or below required thresholds. Mass density efficiency, defined as the weight per unit volume of air, is the best predictor of a filter’s air quality compliance. Ask the filtration manufacturer for a written guarantee of emissions performance stated as grains per cubic foot or milligrams per cubic meter.

6. Use a collector design that ensures safe and easy filter change-out.

The first goal of safe change-out should be no confined space entry – i.e., workers should ideally never have to enter the dust collector to change the filters. Many cartridge-style dust collectors offer this feature, but the giant old-style baghouses still require entry during service, putting workers at risk and requiring companies to file confined space entry permits and monitor for gas.

Are the filters positioned for ease of access? Do they slide in and out of the housing readily? Pulling out a dirty overhead filter that weighs 100 pounds can result in neck, back and foot injuries. Threaded connections on the filter access doors or hoppers are also to be avoided, because dust tends to build up in the threads and cause connections to stick. Camlock-style devices are not subject to this problem and make for easier service.

7. Reduce change-out frequency with long-life filters.

No matter how maintenance-friendly a collector may be, the less service needed, the better – especially in hazardous dust applications. Extended-life cartridge filters available in today’s market can reduce replacement frequency – minimizing worker exposure to dust, saving on maintenance and disposal costs, and reducing landfill impact. Some filter suppliers even offer written guarantees on filter life.

8. Use appropriate fire prevention technologies.

For spark-generating applications, a range of features and technologies are available, from flame-retardant filter media to spark arrestors in the form of drop-out boxes, perforated screens or cyclone devices installed at collector inlets. Fire sprinkler systems may also be required with some installations.

Dust collectors that use vertically-mounted filter cartridges also reduce fire and explosion risks. With horizontally-mounted systems, dust becomes entrained at the top of the filters, and there is no pre-separation of heavy or abrasive particles from the air stream. This situation can shorten filter life and provide a dusty surface for sparks to ignite. Vertical mounting reduces the load on the filters and helps eliminate these problems.

9. Equip your collector with additional safety accessories as needed.

OSHA-compliant railed safety platforms and caged ladders can prevent slips and falls when workers access the collector for service. Lock-out/tag-out doors prevent injury caused by inadvertent opening of doors during a pulsing cycle and/or exposure to hazardous dust. Where highly toxic dust is being handled, for example in many pharmaceutical processing applications, a bag-in/bag-out (BIBO) containment system may be required to isolate workers from used filters during change-out.

10. Use a safety monitoring filter.

Many collectors today are equipped with a safety monitoring filter system. This is a secondary bank of high efficiency air filters that prevent collected dust from re-entering the workspace if there should be a leak in the dust collector’s primary filtering system.

A safety monitoring filter is a required component in a recirculating dust collection system that recycles air downstream of the collector. By recirculating heated or cooled air back through the plant, the cost to replace that conditioned air is eliminated, with rapid paybacks in energy savings. Another advantage of recirculating systems is a reduction in regulatory paperwork. By containing the air indoors, you can avoid the time-consuming permitting involved when contaminated air is exhausted outside.

Scores: 9-10 – excellent; 7-8 – very good; 5-6 – average but room for improvement; 4 or below – time to develop an improved safety plan!

Source: Camfil Air Pollution Control

Download Center

HTML - No Current Item Deck
  • Safety Management Software - Free Demo

    IndustrySafe Safety Software’s comprehensive suite of modules help organizations to record and manage incidents, inspections, hazards, behavior based safety observations, and much more. Improve safety with an easy to use tool for tracking, notifying and reporting on key safety data.

  • Create Flexible Safety Dashboards

    IndustrySafe’s Dashboard Module allows organizations allows you to easily create and view safety KPIs to help you make informed business decisions. Our best of breed default indicators can also save you valuable time and effort in monitoring safety metrics.

  • Schedule and Record Observations

    IndustrySafe's mobile app allows managers, supervisors, and employees to conduct observations on employees involved in safety critical behavior on the go, with or without an internet connection. IndustrySafe’s pre-built BBS checklists may be used as is, or can be customized to better suit the needs of your organization.

  • The 4 Stages of an Incident Investigation

    So, your workplace has just experienced an incident resulting in the injury or illness of a worker. Now what? OSHA recommends that you conduct investigations of workplace incidents using a four-step system.

  • Why Is Near Miss Reporting Important?

    A near miss is an accident that's waiting to happen. Learn how to investigate these close calls and prevent more serious incidents from occurring in the future.

  • Industry Safe
comments powered by Disqus

Free Whitepaper

Stand Your Ground: A Guide to Slip Resistance in Industrial Safety Footwear

This white paper helps to clarify this complexity, so you can better navigate the standards and better ensure the safety of your employees.

Download Now →

OH&S Digital Edition

  • OHS Magazine Digital Edition - October 2019

    October 2019

    Featuring:

    • WINTER HAZARDS
      Preparing for Old Man Winter's Arrival
    • CONSTRUCTION
      Staying Safe in the Trenches
    • INDUSTRIAL HYGIENE
      Setting a Higher Standard: The Limitations of Regulatory Limits
    • ELECTRICAL SAFETY
      Five Important Things to Know About Arc Flash PPE Programs
    View This Issue